Symptom
Check Point
1. Over cooling in
Freezer compartment
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4.Check the Fan motor sticky
5. Check the Fan motor voltage
8-17. Over cooling in Freezer compartment
Duct
Fan Motor
CON5 12
th
pin ~ 11
th
Pin
Resistance [
Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
TEST MODE 1
Voltage [V]
CON3 8
th
pin ~ 5
th
Pin
12V
CON5 6
th
pin ~ 5
th
Pin
0V<Voltage<5V
CON5 7
th
pin ~ 5
th
Pin
0V<Voltage<5V
Duct
Status
Air Flow
Windy
Air Temperature
Cold