12
Installation
All supporting parts should be secured to firm wood, masonry,
or metal.
1. This unit is designed for installation in standard double hung
windows with actual opening widths from 2
9
" to 41".
The top and bottom window sashes must open sufficiently to
allow a clear vertical opening of 18" from the bottom of the
upper sash to the window stool.
2. The stool offset (height between the stool and sill) must be
less than 1 1/4".
NOTICE
2
9
41
18
(Keep the screws for Iater use.)
Remove 4 screws which fasten the cabinet at both
sides and at the back.
pan
(
adhesive backed
)
1.
2.
3.
4.
frame guides
(
Adhesive backed
)
Preparation Of Chassis
Window Requirements