Page 1: ...Operating Instructions LVC S10 LVC S101 LVC S20 LVC S201 Before installing and using the camera please read these instructions throughly and retain them for later reference ...

Page 2: ...nt and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within th...

Page 3: ...ed Device Built in Digital Zoom x2 Easy operation for lens application C CS Adjustment type mount Built in Motion Detection External Sync Line Lock Genlock VD Lock On Screen display Isolated power circuit Maintence of the unit Remove dust or dirt on the surface of the lens with a blower Use a dry soft cloth to clean the body If it is very dirty use a cloth dampended with a small quantity of neutra...

Page 4: ...andling of the unit Be careful not to spill water or other liquids on the unit Be cautions not to get combustible or metallic material inside the body If used with foreign matter inside the camera is liable to fail or to get a cause of fire or electric shock Operating and storage location Avoid viewing a very bright object such as light fittings during an extended period Avoid operating or storing...

Page 5: ... 4 Terminals are used to connect the auto iris lens which should be connected by wire The first terminal from the left is used to connect Alarm Output 9 Power Cord Socket This socket is used to connect the power cord 10 Auto Iris Lens Selection Switch This switch is used to set the mode with user s preference user selection 11 V PHASE adjustment screw 12 AC DC Compatible Input Terminal DC12V AC24V...

Page 6: ...djusted within the range approximately from 90o to 90o Switch the display on the monitor from camera1 to camera2 Adjust the V PHASE volume on camera2 until the vertical roll of the image stops If more than two cameras are used please repeat this procedure for all the cameras If you can t adjust vertical sync phase Please exchange the polarity of input terminal Camera switcher Monitor Vertical phas...

Page 7: ...nnect the power cord to the AC DC compatible terminals on rear panel of the camera Note Be cautious of the polarity of positive and negative Be sure to confirm DC 12V 2V 2 AC 24V Power Supply Connect the power cable to the AC DC compatible input terminal on the rear panel of the camera Note To get the optimum performance from the unit be sure to connect to an AC supply of 24V 10 Connecting the mon...

Page 8: ... Video lens Notes Rotate the lever clockwise until it stops If the lever is not at the end the inner glass or CCD image sensor may be damaged Auto Iris 4 Pin Plug Connector Alarm Connection 1 Connect the alarm out from terminal to VCR or other equipment 2 Set the alarm mode by using Menu function see page 13 Notes Alarm GND is shared with Auto Iris GND 8 Lens No Connection DC 1 2 3 4 Damp Damp Dri...

Page 9: ...he flange back adjusting lever 2 Turn the flange back adjusting lever to the proper focus position 3 Tighten the screws with driver on the flange back adjusting lever BACK FOCUS ADJUSTMENT Lever 1 2 3 Flange Back adjusting lever ...

Page 10: ...10 This camera is mounted with tripod which makes it possible to install from both of the bottom and the top of the unit as illustrated INSTALLATION OF CAMERA ...

Page 11: ... 1 Back Light On Off Sharpness Normal Soft Sharp WBC Mode ATW AWC Sync Mode INT LL Shutter ELC DC Video AGC On Off Brightness ATW R B INT LL Manual Selection VD VS Automatic Selection Push Auto Brightness Up Down Auto Flickerless Shutter Up Down ...

Page 12: ...12 MENU 2 Camera ID On Off Wide Burst On Off Level Set Area Set ID Set Motion DET On Off Inital Set On Off Sensitivity ...

Page 13: ...used to select function Left Right Button This button is used to set or adjust parameters Center Button This button is used to access menu mode and exit the menu The function of Digital Zoom is directly operated with Left Right button Left button is telephoto key and Right button is wide angle Key Opening the Setup Menu Press and hold down for two seconds or longer and the OSD Menu appears on the ...

Page 14: ... 1 250 1 500 1 1000 1 2000 1 4000 and 1 10000 Notes This function is effective with DC or Video Iris Mode 3 AGC Setting Use the button to move the cursor to AGC Use the button to set the AGC On Off mode 4 BACKLIGHT Setting Use the button to move the cursor to BACKLIGHT Use the button to set the BLC On Off mode 5 SHARPNESS Setting Use the button to move the cursor to SHARPNESS Use the button to set...

Page 15: ...ed The range of color temperature is approximately from 2300K to 9000K AWC Mode White Balance is fixed and Push Auto White Mode is operated only by pressing the center button 7 SYNC MODE Setting Use the button to move the cursor to SYNC MODE Use the button to set the LL Line lock or INT internal Whenever the VBS or the VD signals are supplied to GENLOCK input jack the camera switches automatically...

Page 16: ... Use the button to move the cursor to SENSITIVITY Use the button to adjust the sensitivity of motion detection Set the area of Motion Detection Press the button to move submenu Use the button to move the cursor to MASK AREA SET Use the button to move to mask position Use the button to set the mask use or not White Mask indicates exception of motion detection There are five mask area in this camera...

Page 17: ...Use the button and button to move the cursor to the characters that you want Use the button to set the characters Use the button to set the mask use or not To change the characters Use the button to move the cursor to Use button to move the cursor to characters that you want and repeat the above steps for ID Setting To change ID display location Use the button to move the cursor to POSI Press the ...

Page 18: ...IX Mode If you select x32 AUTO for example the sensitivity is raised automatically to x32 Max If you select x32 FIX for example the sensitivity is raised to just x32 When AUTO is selected AGC is automatically set to ON 5 INITIAL Setting All Reset allows you to reset all menu items to the factory settings if you are unsure whether all the modes were set up correctly or not Use the button to move th...

Page 19: ...n 48dB Standard Illuminance 2000Lux 3200 K Sensitivity 1 3 Output 0 5Lux F1 0 0 4Lux F1 0 0 5Lux F1 0 0 4Lux F1 0 Video Output Signal 1Vp p Composite 75Ω Gain Control ON OFF Electronic Exposure Electronic Shutter 1 60 1 10000 Electronic Shutter 1 50 1 10000 Shutter Speed 8 Step with Flickerless Normal 1 60 8 Step with Flickerless Normal 1 50 White Balance ATW AWC Push Auto Back Light ON OFF Bright...

Page 20: ...io More than 48dB Standard Illuminance 2000Lux 3200 K Sensitivity 1 3 Output 0 5Lux F1 0 0 4Lux F1 0 0 5Lux F1 0 0 4Lux F1 0 Video Output Signal 1Vp p Composite 75Ω Gain Control ON OFF Electronic Exposure Electronic Shutter 1 60 1 10000 Electronic Shutter 1 50 1 10000 Shutter Speed 8 Step with Flickerless Normal 1 60 8 Step with Flickerless Normal 1 50 White Balance ATW AWC Push Auto Back Light ON...

Page 21: ... Standard Illuminance 2000Lux 3200 K Sensitivity 1 3 Output 0 005Lux F1 0 Video Output Signal 1Vp p Composite 75Ω Gain Control ON OFF Electronic Exposure Electronic Shutter 1 60 1 10000 Electronic Shutter 1 50 1 10000 Shutter Speed 8 Step with Flickerless Normal 1 60 8 Step with Flickerless Normal 1 50 White Balance ATW AWC Push Auto Back Light ON OFF Bright control Manual Up Down Motion Detection...

Page 22: ...n 48dB Standard Illuminance 2000Lux 3200 K Sensitivity 1 3 Output 0 005Lux F1 0 Video Output Signal 1Vp p Composite 75Ω Gain Control ON OFF Electronic Exposure Electronic Shutter 1 60 1 10000 Electronic Shutter 1 50 1 10000 Shutter Speed 8 Step with Flickerless Normal 1 60 8 Step with Flickerless Normal 1 50 White Balance ATW AWC Push Auto Back Light ON OFF Bright control Manual Up Down Motion Det...