Functions
•
Room temperature sensor. (Thermistor)
•
Maintains the room temperature in accordance with the Setting Temp.
•
Indoor fan is delayed for 5 seconds at the starting.
•
Restarting is inhibited for approx. 3 minutes.
•
High, Med, Low, Chaos
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode or Hot Start Mode (only Heating Model)
--- Lights up during compressor running
(only Cooling Model)
•
Intermittent operation of fan at low speed.
•
The fan is switched to low(Cooling), med(Heating) speed.
•
The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
•
The fan is switched to intermittent or irregular operation
•
The fan speed is automatically switched from high to low
speed.
•
The louver can be set at the desired position or swing
up and down, right and left (not on all models) automatically.
•
The setting temperature, indoor fan speed and desired
operation made are automatically set by fuzzy rule.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
•
Both the indoor and outdoor fan
stops during deicing.
•
Hot start after deice ends.
•
The indoor fan stops until the
evaporator piping temperature
will be reached at 28°C.
Deice (defrost) control (Heating)
Hot-start Control (Heating)
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
Auto Operation
–3–