–19–
[Air inlet side view]
The power cord connected to the outdoor unit should be complied
with the following specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
The connecting cable connected to the indoor and outdoor unit should
be complied with the following specifications (Rubber insulation,
type H05RN-F approved by HAR or SAA).
CAUTION
8.5mm
20mm
GN/YL
7.5mm
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
Terminal Block of Indoor Unit
3(L) 4(N)
5
6
7
1(L) 2(N)
3(L) 4(N)
5
6
7
8
Terminal Block of Outdoor Unit
Power Cord
Terminal Block of Indoor Unit
3(L) 4(N)
5
6
7
1(L) 2(N)
3(L) 4(N)
5
6
7
8
Terminal Block of Outdoor Unit
Power Cord
Control box cover
Indoor
power cord
Remote
controller
cord
Control box cover
fitting screw(2 units)
5. Wiring Connection
• Open the control box cover and connect the Remote controller cord and Indoor power wires.
• Heat Pump Model
• Cooling Model
Make sure that the screws of the terminal are free from looseness.
WARNING
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufac-
turer or its service agent.