–18–
8. LT-B3621HL/B3661HL
Outdoor Unit Wiring Diagram
NOTE
BL : BLUE
BK : BLACK
BR : BROWN
OR : ORANGE GN/YL : GREEN/YELLOW
63H2
C TH
20SV
52C
Cr
HIGH PRESSURE SWITCH FOR HEATING
THERMISTOR FOR PIPE TEMP.
REVERSING COIL
MAGNECTIC CONTACTOR
RUN CAPACITOR FOR CM
TM
52F1
CM
Co
FMo
MAIN TERMINAL BLOCK
RELAY FOR FMo
COMPRESSOR
RUN CAPACITOR FOR FMo
OUTDOOR FAN MOTOR
F1
DP
CH1
THMO
52F2
FUSE (250V, 5A)
DEICER PCB
CRANK CASE HEATER FOR CM
THEMOSTAT FOR COOLING
RELAY FOR FMO CONTROL.
P/NO : 3854A30042L
RD : RED
WH : WHITE
YL :
YELLOW
WIRING OF FIELD
(CONNECTING WIRE)
TM
POWER SUPPLY
BK
63H2
Cr
52C
CH1
BK
BK
BK
BK
L1
T1
L2
T2
B
A
WH
BK
TNS
NO
C TH
NC
D.P
WH
T/B1
BK
WH
WH
BK
WH
BL BK
BK
RD
R
C
S
CM
YL
WH
WH
GN/YL
WH
BL
BK
1
(
N
)
2
(
L
)
Co
OR YL BL BK
OR YL BL BK
Co
FMo
1
FMo
2
20SV BK
BK
BK
BK
WH
YL
WH
YL
BL
BL
THMO
C
L
H
GN/YL
T
O
INDOOR
3(N)
4(L)
5
6
7
7
8
52F2
1
2
3
4
5
6
7
8
52F1
1
2
3
4
5
6
F1