TROUBLE DIAGNOSIS
- 70 -
Problems
Causes
Checks
Measures
Remarks
High
Cycle pipe is clogged.
Check sequence.
- Maybe evacuate should be the first
Direr must be replaced.
temperature in
1. Check temperature of condenser
step here. If the servicer puts a torch
the freezer
manually.
to a charged system, the joint will
compartment.
If it is warm, OK.
explode and spray refrigerant on him.
If it is not, compressor discharging
Also, if oil is forced out, it could
joints might be clogged.
create a fire or safety hazard.
2. Manually check whether hot line
- If it's warm, OK. If it's not,
pipe is warm.
condenser discharging line weld
If it is warm, OK.
joints might be clogged.
If it is not, condenser outlet weld
D
ischarge the system and recover the
joints might be colgged.
refrigerant. Then use a torch to
disconnect unbraze the piping to repair
the obstruction. Repair, evacuate the
system, and recharge it before testing.
Leak at loop pipe weld joint
Check sequence.
Replace the compressor, weld,
Drier must be replaced.
(discharge) in compressor.
1. Manually check whether
evacuate, and recharge refrigerant.
condenser is warm, It is not warm
and the frost forms partly on the
evaporator in the freezer
compartment.
Faulty cooling fan in the compressor
Check sequence.
- Replace if motor does not operate.
compartment.
1. Check cooling fan operation.
- If fan is disconnected, check fan
2. Check that cooling fan is
damage and reassemble it.
disconnected from the motor.
■
Refer to fan motor disassembly
and assembly sequence.
Summary of Contents for LSC 27950SB
Page 22: ... 2 GR L277SSWA LSC27960ST MICOM FUNCTION 22 ...
Page 42: ... 2 GR L277SSWA LSC27960ST EXPLANATION FOR MICOM CIRCUIT 42 ...
Page 47: ...EXPLANATION FOR MICOM CIRCUIT 47 ...
Page 51: ...EXPLANATION FOR MICOM CIRCUIT 51 ...
Page 55: ... 1 GR L277SV S VA LSC27950SW LSC27950SB LSC27950ST CIRCUIT 55 ...
Page 56: ... 56 2 GR L277SSWA LSC27960ST CIRCUIT ...
Page 107: ...ICE WATER PART Optional part EXPLODED VIEW 117 EV 404A 625A 616G 619A 627A 616F ...