1-6. Door opening sensing circuit
(1) GR-L277SV(S)VA, SSWA (LSC27950SW, LSC27950SB, LSC27950ST, LSC27960ST)
✽
Since door switches (A) and (B) are interconnected, if either fails, the other will not respond properly.
✽
If either switch fails, the light will not come on.
EXPLANATION FOR MICOM CIRCUIT
- 31 -
Closing
5 V ( A - B , C - D . Switch at both ends are at Off status)
Opening
0 V ( A - B , C - D . Switch at both ends are at On status)
Measuring part
IC1 (MICOM) No. (44, 45) / (45, 46) / (47, 48) Pin
Door of Freezer and Refrigerator