-53-
• Confirm that the Inlet Grille is normally geared with the shaft of Stepping
Motor.
• If the regular torque is detected when moving the Inlet Grille with hands
Normal
• Check the connecting condition of CN-SUC Connector
• Check the soldering condition(on PWB) of CN-SUC Connector
If there are no problems after above checks
• Confirm the assembly conditions that are catching and interfering parts
in the rotation radial of the Inlet Grille
7. When Inlet Grille does not operate.
Check the operating circuit of the Inlet Grille
• Confirm that there is DC +12V between pin
(RED) of CN-SUC and
GND.
• Confirm that there is a soldering short at following terminals.
- Between
,
,
and
of MICOM
- Between
,
,
and
of IC01G
- Between
,
,
and
of IC01G
Summary of Contents for LS-C076Z Series
Page 67: ...MEMO 67 ...
Page 68: ... 68 MEMO ...