10) Cooling BLDC FAN Motor Error
No
Checking flow
Result & SVC Action
airflow
No airflow
Go to the 4
Go to the 3
Status
SVC Action
8~15 Vdc
Below 1V or 16V
Normal
Change the PCB
SVC Action
1~4 Vdc
Other
Normal
Change the PCB
Status
SVC Action
1
Push the TEST Mode Check the
loose connection
Input Test 1 Mode.
(push the button 1 times)
It feel stuck or locked up, change the
motor.
2
Check the Fan motor rotate in machine
room. (While an error code is displayed,
the fan is not working)
4
Check the FAN Motor Voltage in wires
Red to Black.
COLDEST
COLD