![LG LRSES2706V /01 Service Manual Download Page 63](http://html.mh-extra.com/html/lg/lrses2706v-01/lrses2706v-01_service-manual_1902092063.webp)
6. Poor/Over cooling in Fresh food section
1. Poor cooling in Fresh
food section
Symptom
Check Point
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4. Check the R-Damper motor voltage
CON6
R1SNR
Resistance
[Ω]
23ºF /-5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Duct
Status
Air Flow
Windy
Air Temperature
Cold
Duct
Fan Motor
CON7
CON8
TEST MODE 1
Voltage
[V]
CON8 9
th
pin ~ 12
th
pin
10~12 VDC
CON8 9
th
pin ~ 19
th
pin
2~4.5 VDC
CON8 9
th
pin ~ 10
th
pin
Not 0V, 5V
19
th
pin~20
th
pin
CON7
CON8
63
Copyright © 2020 LG Electronics Inc. All rights
reserved. Only training and service purposes.