![LG LRSES2706V /01 Service Manual Download Page 36](http://html.mh-extra.com/html/lg/lrses2706v-01/lrses2706v-01_service-manual_1902092036.webp)
Troubleshooting
Freezer Sensor Error (E FS)
1
Reconnect or
repair the
connector
Is the Connector disconnected
or loose between Main PCB and
sensor?
Yes
No
2
Check the Sensor resistance.
Yes
No
Change the
Sensor
3
Check the Sensor resistance.
Is resistance OFF (Sensor open)?
Yes
No
Replace the
refrigerator
4
Check the Sensor resistance.
Is resistance normal?
Yes
5
Check the Temperature and
resistance refer to the table.
No problem?
Yes
6
Explain to customer
CON8
CON8
CON8
23
th
pin ~ 24
th
pin
Resistance
[ohm]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
36
Copyright © 2020 LG Electronics Inc. All rights
reserved. Only training and service purposes.