(3) CHECKOUT PROCEDURES FOR CIRCUIT BOARD
The following symptoms indicate a defective circuit
board.
(1) Check the input current. If the input current is more
than 20A, check the magnetron and wiring. If the
input current is less than 0.5 A, there is no input to
the inverter.
(2) The start function fails to operate but the interlock
switches, the door sensing and the relay check
good.
(3) The unit with a normal relay continuously operates.
(4) The buzzer does not sound or continues to sound.
(5) Some segments of one or more digits do not light
up, or they continue to light up, or segments light
when they should not.
(6) Wrong figures appear.
(7) The figures of all digits flicker.
(8) Some of the indicators do no light up.
(9) The clock does not keep time properly.