10-7
CHECKING FLOW CHART BY FAILURE
Oven does not heat
Normal?
END
No
Yes
Yes
Check the resistance of each ignitor
(measure the resistance after cooling down)
Normal:approximately 45Ω~400Ω
Check the resistance of Gas valve
Normal:approximately 1~1.5Ω
Reconnect.
In case of defective harness,
replace or fix
Normal?
END
No
Replace the failed ignitor
Baker ignitor
Broil ignitor
Bake Gas Valve
Pin No.
Broil Gas Valve
1pin
WH
N
1
4
3
2
3pin