4-2
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
Components
Test procedures
Results
Door switch
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Door closed
Continuity
Infinite
Oven lamp
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Below 5 Ω.
If not replace
Bake heater
1. Remove wire leads
2. Measure resistance after cooling down
Normal : Approximately 23Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was
tested at room
temperature (77F/25˚C)
Be careful the element is
sensitive to temperature.
Broil heater
1. Remove wire leads
2. Measure resistance after cooling down
Normal : Approximately 13.7Ω
Abnomal : Infinite(opened)
NOTE: Ω Value was
tested at room
temperature (77F/25˚C)
Be careful the element is
sensitive to temperature.