F-CODE FLOW CHART
Code
Error mode
Operation
Times/sampling
F-6
Opened Sensor
Warm Drawer Thermistor open Over 1 min after warm
drawer operates
During operate
Warming drawer sensing failed
Disconnect power
Warming drawer sensing error
F-6 error
Check for loose warming drawer sensor
connector.
Check the warming drawer sensor
(measure the resistance after cooling down)
Normal:approximately 4.6k
Ω
Normal?
END
Reconnect
No
Yes
Normal?
Replace the warming drawer sensor
END
No
Yes
Continued on the next page