6-9
FAILURE MODE FLOW CHART
Cook-top does not heat
Normal?
Reconnect.
Remove the cook-top relay PCB(011D) harness
and pull the cook-top relay PCB(011D) forward from the PCB case
Inspect the cook-top relay PCB(011D)
Wide pattern(Live part) blown out
pin to pin short or connector harness damaged
Normal?
END
No
No
Yes
Repair and fix
END
Replace the
Cook-top relay PCB(011D)
END
Replace
the main PCB(009E)
Repairable
by yourself?
Yes
No
Yes