9
Setting the Switch
The DIP switch of the camera is one 8-bit switches
and employs RS-485 communication mode as basic
use. Switch settings are read into the camera when
the power is turned on. Make sure to turn it off, then
turn it back after changing the switch settings.
RS-485 Parameter Setup
The selected protocol,communication parameters,
and set unit numbers are read into the camera when
power is switched on.
1. Turn off the camera.
2. Remove the dome cover from the camera.
3. Separate the dome camera body from camera
mounting bracket.
4. Set the DIP switch on the bottom part of the cam-
era according to the function shown in the table of
the below.
5. Turn on the camera. Setup is completed.
ON
1
2
3
4
5
6
7
8
ON
OFF
SW2 on main board
Switch position (5~8)
Function Effect
When the camera is connected to the controller with LG Multix protocol.
The controller with LG Multix protocol allow all control for this camera.
When the camera is connected to the controller with LG protocol.
The controller with LG protocol allow only limited control for this camera.
When the camera is connected to the controller with Pelco P protocol.
The controller with Pelco P protocol allow only limited control for this camera.
When the camera is connected to the controller with Pelco D protocol.
The controller with Pelco D protocol allow only limited control for this camera.
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
Switch position (1~4)
Function Effect
Switch position (1~4)
Function Effect
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
ON
1
2
3
4
5
6
7
8
Note:
If you are not using the controller with LG protocol, there may be some limitation of function control.
Baud Rate 9,600 BPS
communication speed
Baud Rate 1,200 BPS
communication speed
Baud Rate 2,400 BPS
communication speed
Baud Rate 4,800 BPS
communication speed
Baud Rate 19,200 BPS
communication speed
Baud Rate 38,400 BPS
communication speed
Baud Rate 57,600 BPS
communication speed
Baud Rate 115,200 BPS
communication speed
LPT-EP500_ENG 12/24/07 1:34 PM Page 9