Page 1: ...Reserved OWNER S MANUAL AIR CONDITIONER Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times TYPE PORTABLE AIR CONDITIONER LP0821GSSM LP1021BSSM LP1021BHSM Rev 02 ENGLISH ESPAÑOL Caution risk of fire ...

Page 2: ...ontents of Installation Kit 11 Selection of Installation Location 12 Assembling the Flexible Vent Hose Set 12 Attaching the Flexible Vent Hose Set 13 Window Vent Panel and Extensions 14 Installing Vent Panels 16 Drain Hose Installation for Heating On Some Models 17 Garden Hose Installation for Dehumidifying Dry Mode Only 23 MAINTENANCE 23 Emptying the Water Collection Tank 23 Cleaning the Case 23 ...

Page 3: ...G You may be killed or seriously injured if you do not follow instructions CAUTION You may be injured or cause damage to the product if you do not follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what may happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING injury to persons when...

Page 4: ... it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions other appliance OPERATION Use this appliance only for its intended purpose Never attempt to operate this appliance if it is damaged malfunctioning partially disassembled or has missing or broken parts including a damaged cord or plug Repair or immediately replace all power cords that have become frayed ...

Page 5: ...ower outlet to minimize the hazard of electric shock receptacle is properly grounded DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG Have the wall receptacle and circuit checked by a qualified electrician to make sure the Situations when the appliance will be disconnected occasionally Because of potential safety hazards we strongly discourage the use of an adapter plug However if y...

Page 6: ...l not to pinch crush or damage the power cord Make sure the air inlet and outlet are free from obstructions Use a soft cloth to clean the appliance Do not use waxes thinners or harsh detergents Do not step on or place heavy objects on top of the appliance Do not drink water drained from the appliance are used simultaneously Remove the batteries if the remote control is not to be used for an extend...

Page 7: ...H SAFETY INSTRUCTIONS Caution risk of fire The maximum refrigerant charge amount Refer to nameplate marking refrigerant amount The appliance shall be suitable stored to prevent mechanical damage from occurring ...

Page 8: ...hange depending on model 7 8 Connect a garden hose for continuous drainage when running the air conditioner in Dry mode 7 9 CONTINUOUS DRAIN PORT 8 10 PUMP DRAIN PORT On Some Models Connect the provided pump drain hose for drainage when running the air conditioner in Heat mode 11 PUMP DRAIN HOSE On Some Models Connect to the pump drain port for pump drainage when running the air conditioner in Hea...

Page 9: ...serious injury or death Do not use an extension cord with this portable air conditioner Do not use surge protectors or multi outlet adapters with this portable air conditioner Never push the TEST button during operation Doing so can damage the plug Do not remove modify or immerse this plug If this device trips the cause should be corrected before further use CAUTION The conductors inside this cord...

Page 10: ...ner for use in the remote control Do not use a rechargeable battery Make sure that the battery is new In order to prevent discharge remove the battery from the remote control if the air conditioner is not going to be used for an extended period of time Keep the remote control away from extremely hot or humid places To maintain optimal operation of the remote control the remote sensor should not be...

Page 11: ...f Installation Location 2 Security brackets 2 Long adhesive foam seals 1 Non adhesive foam seal 4 Type A screws 1 2 1 Drain hose on some models 1 Lock nut on some models 2 Short adhesive foam seals 4 Type B screws 3 4 1 Type C screw 5 16 1 Panel A 18 Window vent panel 1 Panel B 9 Extension panel 1 Panel C 17 Extension panel 1 Panel D 17 Extension panel Flexible vent hose set 20 20 20 INSTALLATION ...

Page 12: ...eads with the notch on the flexible vent hose 2 Turn the mounting bracket counterclockwise though 5 rotations or until the flexible vent hose is firmly attached 3 Repeat the process to attach the diffuser to the other end of the flexible vent hose 4 Lock Lock Unlock Unlock Round Type Insert the mounting bracket and rotate it to lock it in place Square Type Insert the mounting bracket and slide it ...

Page 13: ...l Window opening A 18 B 9 C 17 D 17 Fig 18 19 26 27 34 35 50 Screw A 1 Select the panels required based on the window opening as shown above 2 For longer window openings assemble and adjust the panels to fit the window opening Use type A screws included to fix the panels together at the proper length For window openings from 19 to 25 use the window vent panel Panel A and extension Panel B For an 1...

Page 14: ...y Insert the panel assembly in the bottom sash channel Use care when installing the assembly which will now fit very tightly in the opening Close the sash tightly against the top of the panel assembly Measure and cut the included non adhesive foam to fit the window opening Stuff it between the window sashes to prevent air and insects from getting into the room Non adhesive foam seal Long adhesive ...

Page 15: ...iding out of the vent opening If the diffuser is positioned correctly the screw should just clear the edge of the opening in the vent panel You should not have to drill through the vent panel NOTE Best positioning Inverted U shape For a tighter seal use no residue duct tape not provided to seal any gaps around the installed panel assembly around the diffuser and between the sashes For best results...

Page 16: ... the hose is aimed away from nearby surfaces that could be stained or damaged by the draining water 1 To attach the drain hose insert the connector into the pump drain port at the back of the unit until it snaps into place 2 Place the other end of the drain hose in a bucket that holds at least 28 ounces Remember to check and empty the bucket frequently to avoid overflows 3 To detach the drain hose...

Page 17: ...n it and secure the drain hose in place 5 To detach the drain hose from the product push the outer ring of the pump drain port in and pull the connector out 1 Remove the drain plug when using the Dry dehumidifying mode 2 Install a 1 2 12 7 mm inside diameter garden hose not provided into the continuous drain port and place the open end of the hose over a floor drain or bucket NOTE Inserting the dr...

Page 18: ...ON Control Panel and Remote Control 8 9 6 5 4 3 2 1 NOTE Available functions may vary by model The number and location of LEDs on the control panel may vary by model OPERATION 18 8 9 6 5 3 2 4 1 1 5 4 2 7 6 3 ...

Page 19: ... Delay OFF Timer the display returns to the temperature setting after a short delay To cancel the Timer function press the Timer button on control panel Press and hold the Timer button on the control panel for 3 seconds to set Auto Swing 5 19 OPERATION ENGLISH 1 2 Power Turns the air conditioner on and off A chime sounds to confirm you have turned it on or off Mode Press this button repeatedly to ...

Page 20: ...en it is turned off NOTE Some functions cannot be used while this option is turned on 10 Auto Swing This function automatically moves the louvers to adjust the direction of the air flow Press the Auto Swing button repeatedly to select the desired direction NOTE To switch the temperature units on the display between Fahrenheit F and Celsius C press and hold the Swing button on the remote control fo...

Page 21: ...hase a Wi Fi repeater range extender to improve the Wi Fi signal strength The Wi Fi connection may not connect or may be interrupted because of the home network environment The network connection may not work properly depending on the Internet service provider The surrounding wireless environment can make the wireless network service run slowly The appliance cannot be registered due to problems wi...

Page 22: ...hich are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Open Source Software Notice Information To obtain the source code under GPL LGPL MPL and other open source licenses that is contained in this product please visit http opensource lge com In addition to the source code all referred license terms warranty disclaimers and c...

Page 23: ...with a slightly damp cloth then wipe dry with a dry cloth or towel Never pour water onto or into the air condition er It could damage internal components and create a shock and fire hazard Cleaning the Air Filter 1 Pull out each air filter by the handle 2 Use a vacuum cleaner to clean the filters If the filters are heavily soiled they can be washed in warm water using a mild detergent Do not use h...

Page 24: ...errupter device is tripped Press the RESET button located on the power cord plug If the RESET button will not stay engaged discontinue use of the air service technician Air conditioner FL appears in the display Mode switched from Cool to Heat or vice versa does not cool as it should The water collection tank is full Drain the tank and reset your settings blinds or furniture blocking the front Make...

Page 25: ... when unit is cooling Air movement sound Remote sensing deactivating prematurely Remote control not located within range Place remote control within 20 feet 120 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too low Increase set temperature NOTE This is normal If too loud adjust the fan speed to low If you see CH in the display ple...

Page 26: ...26 TROUBLESHOOTING ...

Page 27: ... provided during the warranty period subject to availability within the United States In home service may not be available in all areas To receive in home service the product must be unobstructed and accessible to service personnel If during in home service repair cannot be completed it may be necessary to remove repair and return the product If in home service is unavailable LG may elect at our o...

Page 28: ...NUFACTURER NOR ITS U S DISTRIBUTOR SHALL BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE INCLUDING AND WITHOUT LIMITATION TO LOST REVENUES OR PROFITS OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty l...

Page 29: ...y the Federal Arbitration Act Judgment may be entered on the arbitrator s award in any court of competent jurisdiction All issues are for the arbitrator to decide except that issues relating to the scope and enforceability of the arbitration provision and to the arbitrability of the dispute are for the court to decide The arbitrator is bound by the terms of this provision Governing Law The law of ...

Page 30: ...30 ...

Page 31: ... Information Center Centro de Información al Cliente de LG 1 800 243 0000 Register your product Online Centro de Información al Cliente de LG www lg com LG Electronics Inc 111 Sylvan Ave Englewood Cliffs NJ 07632 ...