- 79 -
11. DESCRIPTION OF FUNCTION & CIRCUIT OF MICOM
11-1 FUNCTION
11-1-1 Function
1. When the appliance is plugged in, it is set to 37°F for Refrigerator and 0°F for freezer.
You can adjust the Refrigerator and the Freezer control temperature by pressing the ADJUST button.
2. When the power is initially applied or restored after a power failure, it is set to Control temperature Previously.
3. If you do not press any button after turning on the power, only CRUSH or CUBE Label that has been selected will be
turned on and all other LEDs on the display Panel will be turned off Within 60 seconds.
4. If you press a button, only CRUSH or CUBE Label that has been selected will be turned on and all other LEDs on the
display Panel will be turned off Within 20 seconds.
11-1-2 How to Toggle the Display between °F & °C
1. The initial setting is °F and the display temperature mode can be changed from °F to °C or °C to °F by pressing and
holding the FRZ TEMP and the REF TEMP keys at the same time for over 5 seconds.
11-1-3 Metered fill function
SETTING THE METERED FILL UNIT
You can change the unit of Metered fill.
As you can see the left, the initial
unit after power on is OZ.
The unit is changed to CUPS
when you press and hold this
button at least 3 seconds and
when you press it again,
changed to OZ.
While water is dispensed, the
numbers will be increase.
5. If you do not want to use the Power Save Mode, you can change the Mode by pressing the ICE PLUS Button and
Freezer TEMP button simultaneously for more than 5 seconds.
11-1-4 Dispenser use selection
SETTING THE DISPENSER
You can select the ice type of the dispenser.
The default setting is CRUSHED
ice.
Press CUBE to get cubes
instead of crushed ice.
Summary of Contents for LMX28994 Series
Page 23: ... 23 5 CIRCUIT DIAGRAM ...