- 44 -
No
1
Checking flow
Check the sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(push the button 1 time)
3
Open the fresh food door and Check the
air flow.
※
The sensor is determined by
the temperature.
For example, 30
㏀
indicates 32°F.
Result & SVC Action
Temperature
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38
㏀
30
㏀
24
㏀
19.5
㏀
16
㏀
Status
Windy
No windy
SVC Action
Go to the 4
Check the R Fan motor
Check the damper
(Go to the 6)
4
Check the air temperature.
Cold or not?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
<CON11>
6) Poor cooling in Fresh food section