- 21 -
6-2 TSD AND OLP
Shows continuity
Open
TSD
-115/
127
V-60H
z-Y
123456789101112
513604000
000000007Z
17/JUL
/06
EECON
JLLE
RoHS
R
Normal operation of
compressor is
impossible or poor.
Separate TSD-Starter
from compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
tester.
(Figure 19)
Separate OLP from
compressor and check
resistance value
between two terminals
of OLP with a tester.
(Figure 20)
Observation value is
115V/60Hz : 6.8
Ω
±30%
The resistance value
is 0
Ω
(short) or
∞
(open).
Check another
electric component.
Replace OLP.
Replace TSD-
Starter.
Figure 19
Figure 20