STEP 3:
Prepare The Venting Blower
WALL-VENTED INSTALLATION:
1. Remove one blower unit mounting screw and one or
several blower plate mounting screw(s). Remove the
blower plate from cabinet. See Figure 1
2
.
2. Carefully lift the blower unit out of the microwave oven.
3. Use side cutters or tin snips to cut and remove knockouts
B from Back plate. Discard knockouts. Be careful not to
distort the plate. See Figure 1
3
.
4. Reassemble the blower wire. See Figure 1
4
.
5. Rotate the blower unit so that the exhaust ports face the
rear of the cabinet. See Figure 1
5
.
6. Place blower unit back into cabinet. Check that the exhaust
ports face towards the rear of the cabinet. Be sure the
wires are not pinched. See Figure 1
6
.
7. Reattach the blower plate to cabinet so the exhaust ports
and blower plate opening are aligned. Attach with one
blower unit mounting screw and then one or several blower
plate mounting screw(s). See Figure 1
7
.
Figure 1
2
Blower Plate
Mounting Screw
Blower Plate
Back Plate
Blower Unit
Mounting Screw
Blower Unit
Parts B
Figure 1
3
Parts B
Knockouts Parts B
Blower
Unit
Exhaust Ports
180°
Figure 1
4
Figure 1
5
Figure 1
7
Blower Plate
Mounting Screw
Blower Plate
Back Plate
Blower Unit
Exhaust Ports
Blower Unit
Blower Unit
Mounting Screw
Figure 1
6
Exhaust
Ports
–
10
–
8
.
Insert the tabs on each side of the damper into the holes
at the inside rear of the adaptor.
Slide exhaust
adaptor into
guides on
rear panel.
Exhaust Adaptor
Damper
(hinge side up)
Locking
Tabs
Guides
Figure
18
Attach the exhaust adaptor to the
back plate wall side.
Push in securely until it is past the
top locking tabs
and in the lower locking tabs. Take care to
assure
the damper hinge is installed so that it is at the top
and that the damper swings freely.
See Figure 18.
Summary of Contents for LMV1831BDLG