Refrigerant Line Specifications
***
Pipe Size
Additional
Max. Pipe
Max.
Type
System
Model
BTUs
Liquid
Suction
Refrigerant
Length
Elevation
Flex Multi Split
A/C
LMI090CP
9,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
A/C
LMA090CP
9,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
A/C
LMI120CP
12,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
A/C
LMA120CP
12,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
A/C
LMA121CPM
12,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
H/P
LMI090HP
9,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
H/P
LMA090HP
9,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
H/P
LMI120HP
12,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
H/P
LMA120HP
12,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
H/P
LMA121HPM
12,000
1/4
”
3/8
”
0.22 oz./ft.
50
’
25
’
Electrical Specifications
†
Type
System
Model BTUs
Voltage
Rated
MCA
*
MOP
**
Indoor
Outdoor
Amps
Flex Multi
A/C
LMI090CP
9,000
36V DC
–
0.5
–
–
Split Indoor
A/C
LMA090CP
9,000
36V DC
–
1.3
–
–
Units
A/C
LMI120CP
12,000
36V DC
–
0.5
–
–
A/C
LMA120CP
12,000
36V DC
–
1.3
–
–
A/C
LMA121CPM
12,000
36V DC
–
0.5
–
–
H/P
LMI090HP
9,000
36V DC
–
0.5
–
–
H/P
LMA090HP
9,000
36V DC
–
1.3
–
–
H/P
LMI120HP
12,000
36V DC
–
0.5
–
–
H/P
LMA120HP
12,000
36V DC
–
1.3
–
–
H/P
LMA121HPM
12,000
36V DC
–
0.5
–
–
Outdoor
A/C
LMO240C
24,000
–
230/208
11.1
20
30
Units
A/C
LMO360C
36,000
–
230/208
16.6
30
40
H/P
LMO240H
24,000
–
230/208
11.1
20
30
H/P
LMO360H
36,000
–
230/208
16.6
30
40
†
All equipment single phase
NOTE: Please consult local electrical codes for proper wire requirements.
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
HIGH WALL DUCTLESS • FLEX MULTI-SPLIT DUAL AND TRI-ZONE
ELECTRICAL AND REFRIGERATION • QUICK REFERENCE
***Each outdoor unit is pre-charged with enough refrigerant to charge the indoor
unit and up to 25 ft. of line set. You must adjust the charge if this length varies.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement: For systems with maximum
elevation of 25 ft. (see chart above and Figure A), refrigerant lines must be oil trapped
between 8 ft. and 16.4 ft. of elevation. For systems with elevation of greater than
25 ft. (see chart above), refrigerant lines must be oil trapped at least every 16.4
ft. of elevation.
Each system should have a 6-8 inch inverted trap at the condensing unit if mounted
above indoor unit.
Figure A:
Oil trap required at
8-16.4 ft. elevation
(condenser over
evaporator).
Indoor Wire Size
Indoor/Outdoor Connecting Cable Minimum AWG
18-4
22
Summary of Contents for LMU365HV
Page 2: ......
Page 7: ...4 THE LG HVAC ADVANTAGE ...
Page 27: ...24 FLEX MULTI SPLIT ...
Page 56: ...53 Stabs bacteria Breaks it Deodorizes ...
Page 57: ...54 NOTES ...
Page 58: ...55 NOTES ...
Page 59: ...NOTES 56 ...
Page 60: ...LG Electronics Canada Inc 1 888 LG Canada 542 2623 LG ca ...