- 22 -
Terminal on the OUTDOOR UNIT
Terminal on the INDOOR UNIT
A-UNIT
Terminal on the INDOOR UNIT
Power cord
B-UNIT
1(L)
2(N)
1(L)
2(N)
3
3
1(L)
2(N)
3
3
2(N)
2(N)
1(L)
1(L)
Outdoor unit
Terminal block
Over 5mm
Cover control
Connecting cable
Power cord
Holder for
power supply
cord
2) Connection of the cable
1. Remove the cover control from the unit by loosen-
ing the screw.
Connect the wires to the terminals on the control
board individually as the following.
2. Secure the cable onto the control board with the
holder (clamper).
3. Refix the cover control to the original position with
the screw.
4. Use a recongnized circuit breaker between the
power source and the unit. A disconnection device
to adequately disconnect all supply lines must be
fitted.
Caution
If a power plug is not to be used, provide a circuit
breaker between power source and the unit as
shown below.
CAUTION
ø
8.5mm
GN/YL
20mm
ø
1.25mm
GN/YL
20mm
The power cord connected to the outdoor unit
should be complied with the following specifica-
tions (Rubber insulation, type H05RN-F
approved by HAR or SAA).
The connecting cable connected to the indoor
and outdoor unit should be complied with the
following specifications (Rubber insulation, type
H07RN-F approved by HAR or SAA).
NORMAL CROSS-
SECTIONAL AREA
1.25mm
2
NORMAL CROSS-
SECTIONAL AREA
2.5mm
2
or 3.5mm
2
Air
Conditioner
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
Main power source