- 15 -
Installation
Front
Right
Rear right
Rear left
Down right
Left
More than 5 cm
More than eye-level
More than
5 cm
More than
5 cm
More than 10 cm
More than 10 cm
More than 70 cm
A
B
Indoor unit
Outdoor unit
1) Selection of the best location
1. Indoor unit
•
There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not
restricted.
• There should not be any animals or plants
which could be affected by hot air discharged.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
3. Piping length and the elevation
Pipe Size
GAS
LIQUID
Max. piping
length
A (m)
Max.
Elevation
B (m)
1/2"(3/8")
1/4"
10~15
5~7
(1) Installation of Indoor, Outdoor unit