outdoor unit reFrigerant FloW diagram
Luu247HV and Luu367HV
cooling / Heating Mode
Refrigerant Flow
Cooling
Heating
M
M
High Pressure
Sensor
4 way
36k/42k model only
Valve
Discharge
Temperature
Thermistor
Suction
Temperature
Fusible
Plug
Thermistor
Accumulator
Inverter
Compressor
Strainer
Strainer
Condenser Out
Temperature
Thermistor
Outdoor Ambient Air
Temperature
Thermistor
Ø3/8
Flare Connection
Ø5/8
Flare Connection
Condensing
Temperature
Thermistor
Electronic
Expansion Valve
Liquid Side
Piping
Vapor Side
Piping
SVC
SVC
Figure 10: LUU247HV and LUU367HV Refrigerant Flow Diagram.
Description (Based on Cooling Mode)
PCB Connector
LUU247HV
LUU367HV
Suction Temperature Thermistor
CN-TH3
CN-TH3
Discharge Temperature Thermistor
Condenser Outlet Temperature Thermistor
CN-TH2
CN-TH2
Outdoor Ambient Air Temperature Thermistor
Condenser Inlet Temperature Thermistor
CN-TH4
CN-TH4
Pressure Sensor
CN-TH1
P-SENSOR(H)
Table 7: Ceiling-Concealed Duct (High Static) Outdoor Unit Thermistor Details.
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
18 | duct (HIgH StatIc)
Ceiling-Concealed Duct (High Static) System Engineering Manual