S P E C I F I C A T I O N
Reg. Date : 2017.09.01
MODEL NAME:
LGSWFAC81
Rev. No. : 1.0
Copyright
ⓒ
. 2016. All Rights Reserved.
5. Operating Conditions
Parameter
Min
Typ
Max
Unit
Ambient Temperature
0
-
60
℃
Ambient Humidity (40
℃
)
-
-
85
%
Supply Voltage
3.135
3.3
3.6
Vdc
6. Standard Test Conditions
The Test for electrical specification shall be performed under the following condition
Otherwise this following conditions, not guaranteed this performance.
Temperature
25
±
5
℃
Humidity
65
±
5%
Input power
Supply Voltage
VCC_3.3V
3.135 ~ 3.6V
6-1. Ambient condition
6-2. Power supply voltages
6-3. Current consumption
Human Body Model (HBM)
Min.
Max.
Unit
Contact
-
±
4
kV
Air
-
±
15
6-4. ESD Information
Note 1 : IEC 61000-4-2 (150pF, 330R)
※
Test condition : After 8-pin USB Cable connect to module, progress ESD test.
Current Consumption
Min.
Typ.
Max.
Unit
TX Mode ( 11ac/80MHz)
-
700
1200
mA
Idle and Associated state
-
270
300
Radio disabled state
-
60
70
Note 1 : This figure is the RMS(root mean square) Value.