- 63 -
4.1.8 Folder ON/OFF Trouble (1)
•
Block Diagram
Calypso
U102
FOLDER
A3212EEH
U302
R310
V_IO
C315
C316
V_IO
FOLDER
U302
C315
•
Folder Operation
- There is a magnet at slide part to detect the
open-or-close status.
- If a magnet is close to the hall-effect
switch(U302), the voltage at pin 1 of U302
goes to 0V. Otherwise, 2.8V.
- This FOLDER_DETECT signal is delivered
to DBB, and then DBB Check the FOLDER
signal status.
•
Folder Signal Status
- L : Close (Magnetized)
- H : Open (Not magnetized)