- 174 -
LGE Internal Use Only
Copyright © 011 LG Electronics. Inc. All right reserved.
Only for training and service purposes
13.AUTO CALIBRATION
12.5 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the result window
will show correction values per every power level and gain code and the same measure is performed per every
frequency.
12.6 APC
This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.
12.7 ADC
This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table will be reset.
11.8 Target Power
29.8 dBm
29.8 dBm
29.8 dBm
Max power
1909.8 MHz
1880 MHz
1850.2 MHz
Frequency
810
661
512
Channel
PCS 1900
29.8 dBm
29.8 dBm
29.8 dBm
Max power
1784.8 MHz
1747.6 MHz
1710.2 MHz
Frequency
885
699
512
Channel
DCS1800
32.8 dBm
32.8 dBm
32.8 dBm
Max power
914.8 MHz
897.4 MHz
880.2 MHz
Frequency
124
37
975
Channel
EGSM 900
32.8 dBm
32.8 dBm
32.8 dBm
Max power
848.8 MHz
836.8 MHz
824.2 MHz
Frequency
251
191
128
Channel
GSM 850
High
Middle
Low
Description
BAND
13.5
13.6
13.7
13.8