LG LG N3C(W)-V6 Series Installation Manual Download Page 11

PRODUCT SPECIFICATIONS

Rated electrical characteristic except power rating within -0/+3 percent are within 5 percent of measured.

Values at Standard Test Condition(STC) : Irradiance 1000W/m

2

, Cell temp. 25

, 1.5AM

Note) MC4 formal name : PV-KST4 / 6II-UR, PV-KBT4 / 6II-UR

→ Plus (+) Connector : Male MC4 coupler (PV-KST4/6II-UR)
→ Negative (-) Connector : Female MC4 coupler (PV-KBT4/6II-UR)

Note) The Typical change in module efficiency at 200W/m

2

in relation to 1000W/m

2

is -2.0% /

‘N3K-V6’ is -3.0%

Female and male cable couplers

Female cable coupler

*

NMOT (Nominal Module Operating Temperature) : Irradiance 800W/m

2

, ambient temperature 20℃, wind speed 1m/s

Temperature Characteristics

* See more information 

>>

http://www.multi-contact.com/ 

o

http://en.ukt-sz.com/ 

Electrical Properties(NMOT*)

Ø

A

Ø

A

Male cable coupler

“Max. No. of modules in series” is considering 125% of Voc. Actual number of connections 
should be selected according to the installation site conditions and local code.

Model

LGXXXN3C(W)-V6

LGXXXN3K-V6

NMOT

[   °C  ]

42±3

42±3

Pmax

[%/°C]

-0.33

-0.33

Voc

[%/°C]

-0.26

-0.26

Isc

[%/°C]

0.04

0.04

Model

LGXXXN3C(W)-V6

LGXXXN3K-V6

395

400

405

410

415

390

395

400

405

410

Maximum Power (Pmax)

[W]

298

302

305

309

313

294 

298 

302 

306 

309 

MPP Voltage (Vmpp)

[V]

34.2

34.5

34.9

35.3

35.7

34.3 

34.6 

35.0 

35.4 

35.8 

MPP Current (Impp)

[A]

8.72

8.73

8.75

8.76

8.77

8.59 

8.60 

8.62 

8.64 

8.64 

Open Circuit Voltage (Voc)

[V]

42.0

42.2

42.4

42.6

42.8

42.4 

42.5 

42.6 

42.7 

42.8 

Short Circuit Current (Isc)

[A]

9.10

9.14

9.18

9.21

9.25

8.92 

8.96 

8.99

9.02 

9.05 

Model

Cable Cross Section

Ø A (Cable outer diameter)

Rated current

MC4

4mm²

5.5 ~ 9mm

30A

12AWG

Note) Max. Bifaciality Coefficient of Power : N3C(W)-V6 0.04 / N3K-V6 0.06 

Max. Bifaciality Coefficient of Current : N3C(W)-V6 0.05 / N3K-V6 0.07 

Max. Bifaciality Coefficient of Voltage : N3C(W)-V6 0.88 / N3K-V6 0.88

11

Note)   For information about the electrical ratings for both front and back surfaces (Bifaciality Coefficient)

and the expected contribution from ground reflected irradiance  along with ground cover and installation height above ground 

that reflected irradiance, please refer to the sales talk material and datasheet.

Electrical Properties

Mechanical Properties

Module

Series

Model Name

Pmax

at STC

Pmax

at

Bifi100

Pmax

at

Bifi200

Power

Tolerance

Voc at

STC

Isc at

STC

Vmpp at

STC

Impp at

STC

Max.

No of

Module

In series

Max.

Series

Fuse

Rating

Max.

System

Voltage

Connector Length Width Height Weight

W

W

W

%

V

A

V

A

A

V

mm

mm

mm

kg

LG

X

X

X

N

3C

(W

)-

V6

LG395N3C(W)-V6

395

395.8

396.6

0~3%

44.6

11.30 

36.3

10.89 

17

20

1000

MC4

1880

1042

40

19.7

LG400N3C(W)-V6

400

400.8

401.6

0~3%

44.8  11.35 

36.7 

10.90 

17

20

1000

MC4

1880

1042

40

19.7

LG405N3C(W)-V6

405

405.8

406.6

0~3%

45.0  11.40 

37.1 

10.92 

17

20

1000

MC4

1880

1042

40

19.7

LG410N3C(W)-V6

410

410.8

411.6

0~3%

45.2  11.44 

37.5 

10.94 

17

20

1000

MC4

1880

1042

40

19.7

LG415N3C(W)-V6

415

415.8

416.7

0~3%

45.4  11.49 

37.9 

10.95 

17

20

1000

MC4

1880

1042

40

19.7

LG

X

X

X

N

3K

-V6

LG390N3K-V6

390

391.6

393.1

0~3%

45.0  11.08 

36.4

10.72 

17

20

1000

MC4

1880

1042

40

19.7

LG395N3K-V6

395

396.6

398.2

0~3%

45.1  11.12 

36.8 

10.74 

17

20

1000

MC4

1880

1042

40

19.7

LG400N3K-V6

400

401.6

403.2

0~3%

45.2  11.16 

37.2

10.76 

17

20

1000

MC4

1880

1042

40

19.7

LG405N3K-V6

405

406.6

408.2

0~3%

45.3  11.20 

37.6 

10.78 

17

20

1000

MC4

1880

1042

40

19.7

LG410N3K-V6

410

411.6

413.3

0~3%

45.4  11.24 

38.0 

10.79 

17

20

1000

MC4

1880

1042

40

19.7

Summary of Contents for LG N3C(W)-V6 Series

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXN3C W V6 LGXXXN3K V6 www lgsolarusa com Installation manual PV Solar MODULE ...

Page 2: ...tions 06 Diodes 06 Series Connection 06 Parallel Connection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 13 ...

Page 3: ...sult in accide nt or death Damaged modules must be treat ed with safety protection equipme nt Failure to comply may result i n serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junct ion box cable It may occur spar k or electric shock Do not bending junction box s ca ble While under stres...

Page 4: ...e Failure to comply may result in damage of the product If the installing modules on curved surface e g arch ty pe as shown in the below picture do not forcefully mo dify the module in the installation when connecting it wi th the structure Only install the module in the place wh ere the structure for the panels has been properly set u p An improper structure may cause deformation of the panels Pa...

Page 5: ...contact with the panel especially when the p anel is under mechanical load Deposits of foreign material on the frame surface can be cleaned by using a wet sponge or cloth and dried i n air or by using a clean chamois Perform the wiring work by connecting the connector and wires to the stand away from the roof or ground Do not use any kind of oil or lubricant on the module s any parts It can defect...

Page 6: ...n the guidelines on the product specification s heet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is op erating Shock hazard may occur near the solar m odules connection means When the module installing in series or in parallel e g using for extension cables etc the connector of each module should be the same products mated with i...

Page 7: ... recommends that all wiring be double insulated with a minimum rating of 90 C 194 F All Wiring should use a flexible copper Cu conductor The minimum size should be determined by the applicable codes LG Electronics recommends a size no smaller than 12AWG 7 Earth Grounding All work must be conducted in conformance with all Federal State and local codes and standards Grounding works should be perform...

Page 8: ...lls of living places Module Strength Basic Load CSA UL61730 Ym is a safety factor of 1 5 Detail of mounting distance is below This mounting method is by using frame bolt holes The mounting rails must run perpendicularly to the module long side Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it face...

Page 9: ...lipping snow We recommend to use corrosion resistant material according to standard CSA UL61730 for these supporting part A snow guard should be installed in accordance with the manufacturer s instructions Solar module Supporting part Roof Mounting by using frame bolts holes Secure the solar module to the structure by using the factory mounting holes Four M8 stainless steel bolts four nuts four sp...

Page 10: ...demands losses or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies successors or assigns its administrators directors officers volunteer and employees Disposal Please contact your local disposal center or Dealer Distributor TRANSPORTINGAND STORAGE Do not loosen the banding when the module is transported by truck ship and ...

Page 11: ...2AWG Note Max Bifaciality Coefficient of Power N3C W V6 0 04 N3K V6 0 06 Max Bifaciality Coefficient of Current N3C W V6 0 05 N3K V6 0 07 Max Bifaciality Coefficient of Voltage N3C W V6 0 88 N3K V6 0 88 11 Note For information about the electrical ratings for both front and back surfaces Bifaciality Coefficient and the expected contribution from ground reflected irradiance along with ground cover ...

Page 12: ...Dimensions of Modules Unit mm in LGXXXN3C W V6 LGXXXN3K V6 Frame Cross section Long Frame Short Frame 12 ...

Page 13: ... lg solar lge com http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and i ntellectual properties of LG Electronics Inc are protected by international copyright laws ...

Page 14: ...228 890 990 ...

Page 15: ...Note All mechanical installation methods and bolting method in this appendix were not tested by CSA or 3rd party It is evaluated by LG internal test ...

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: