LG LG***N1CK-A3 Installation Instructions Manual Download Page 4

4

Electrical Installation

Before & After Installation

• Dirt build-up on the surface of the panel may cause

active solar cells to be shaded and electrical
performance to be impaired.

• Always keep the back surface of the panel free

from any foreign objects or structural elements
which could come into contact with the panel.

After Installation

• Plug in the connector tightly and ensure that the

wiring properly works.

• Conduct periodic inspection of the panels for

damage to front glass, back sheet, frame, junction
box, or external electrical connections.

• Check electrical connections for loose connections

and corrosion.

• Removal of dirt from the front glass can increase

output.

• Water, ethanol or a conventional glass cleanser

with a micro-fiber cloth can be used for regular
washing or rinsing of the front glass to remove
dust, dirt or other deposits.

• Aggressive and abrasive cleansers or chemicals

such as alkali chemicals including ammonia based
solution should not be used on cleaning the module.

• Always wear rubber gloves for electrical insulation

while maintaining, washing or cleaning panels.

• Deposits of foreign material on the frame surface

can be cleaned by using a wet sponge or cloth and
dried in air or by using a clean chamois.

• Perform the wiring work by connecting the

connector and wires to the stand away from the
roof or ground.

Before Installation

Please carefully read this manual before installation.
• Contact with electrically active parts of the panels,

such as terminals, may result in burns, sparks and
lethal shock whether the panel is connected or
disconnected.

• Panels produce voltage even when not connected

to an electrical circuit or load.

• Solar module installation and maintenance must be

performed by qualified and authorized installer.

• All installation instructions should be read and

understood before performing any installation.

• Do not twist, pull, or scratch the cable attached to

the solar module.

• Do not touch the solar module with bare hands.

Failure to comply may result in a serious burn or
injury.

• Do not drop the solar module or place weight on a

solar module.

• Do not disassemble the solar module.
• After installation or repair, check that the solar

module are operating properly.

• In the event that the currently used solar module or

parts have been replaced the newly replaced
module and parts must have the same model
name and parts as the previously installed solar
module.

• Secure all necessary permits and licenses to install

the solar modules

• Only qualified and authorized individuals are

permitted to treat electrical parts, when there is a
breakage, failure or damage of the product or
damage of the product.

• Do not use or install broken modules; Failure to

comply may result in fire, electric shock, and injury.

• Do not install the module horizontally. Failure to

comply may result in excess dirt or white
efflorescence (glass disease).

• Panels are not intended for use indoors or on

moving vehicles of any kind.

• Reflection from external environments such as

snow Reflection from external environments such
as snow, water or other surfaces may increase the
power generated by the panel.

• Industry standard rated specifications are made at

conditions of 1000W/m 2 irradiance and 25 °C
(77ºF) solar cell temperature. Colder temperatures
may substantially increase voltage and power.

• Keep the solar module and system away from

children at all times.

• Keep the module packed in the carton until the

time of installation.

• Keep flammable gasses away from the installation

site.

• Do not work alone. Please work as part of a team

of two or more people.

• Safety harness use is strongly recommended for

installation.

• Partial shadowing may substantially reduce panel

and system output.

• Care must be taken to avoid low tilt angles which

may cause dirt to buildup on the glass against the
frame edge.

Danger

• Avoid all electrical hazards when installing, wiring,

operating and maintaining all panels.

• Do not connect panels that have different electrical

properties or physical configurations in the same
system.

• Match the polarities of cables and terminals when

making the connections; failure to do so may result
in damage to the panel.

• The rating of the over-current device shall not

exceed the maximum series fuse rating marked on
the name plate.

• The panel contains factory installed bypass diodes

located inside the junction box.

• When installing the system, it is recommended to

install a lightning rod to protect the system.

Summary of Contents for LG***N1CK-A3

Page 1: ...N1C W K A3 LGXXXN1C W K B3 A minimum slope of 5 in ft for installation over a roof is required to maintain the fire class ratings The array frame shall be grounded in accordance with NEC Article 250 Installation Instructions MFL68783801 ...

Page 2: ...iability Disposal 10 7 Transporting and Storage 10 8 Appendix 11 Date Version Remark Description of change 2013 08 13 2014 02 07 2014 09 24 2014 10 14 2014 10 20 2014 11 13 1 0 1st edition 2 0 3 0 4 0 5 0 6 0 Add B3 Model LGXXXN1X B3 Add 305 310W Power output Model Add Appendix Contents Edit to description of Mechanical Installation Edit to Electrical Properties Except K Model ...

Page 3: ...ty gear Contact may result in lethal spark or electric shock Do not use or install if the module is broken or torn Failure to comply may result in electric shock Perform all work in dry conditions and use only dry tools Do not handle wet panels without appropriate protection equipment Failure to comply may result in accident or death accident or death Damaged modules must be treated with safety pr...

Page 4: ... solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Secure all necessary permits and licenses to install the solar modules Only qualified and authorized individual...

Page 5: ...PV output Depending on national directives additional safety factors might be applicable for overcurrent protection The junction box should not be opened Opening the junction box will void the warranty Panels with a suspected electrical problem should be returned to LG Electronics for inspection and possible repair or replacement as per the warranty conditions provided by LG Electronics Electrical...

Page 6: ...should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards Specific information on the solar module dimensions and location of grounding holes is provided in Product Specifications One M4 stainless steel bolt one nut one spring washer two flat washers one cup washer one s...

Page 7: ...r from entering the junction box which could cause a safety hazard Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behind the solar module The recommended standoff height is a minimum of 100mm When installed on a roof the solar module must be mounted over a fire resistant roof covering rated for the...

Page 8: ...frame and two clamps at the center of long Frame Clamping Range 230mm Use four clamps on the Short frame This method is not tested by IEC UL This installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind shield or deflector Clamping Range From module Edge to 270mm Clamping Range From mod...

Page 9: ...rcent Standard Test Condition STC Irradiation 1 000W m2 Cell temp 25 C 1 5AM Dimensions of Modules Note Relative efficiency reduction by respect to irradiance MC4 formal name PV KST4 6II UR PV KBT4 6II UR A safety locking clip MC PV SSH4 may be required per article 690 of NEC 2008 Note Holder is for the convenient connection of junction box cable but that does not warranty if it is broken after in...

Page 10: ...ervice of LG Solar Modules and if applicable from all liabilities claim Solar Modules and if applicable from all liabilities claims demands losses or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies successors or assigns its administrators directors agents officers volunteer and employees Disposal Please contact us if you...

Page 11: ...amples of Rails and WEEBs are included in the following tables Torque 8 12Nm LG Model LGxxxS1C W K A3 LGxxxS1C W K B3 LGxxxN1C W K A3 LGxxxN1C W K B3 Rails and WEEBs Test sample for UL test UGC 1 Top Mounting UniRac Inc Grounding Clips No Rail Washer Clamp Compatibility UGC 1 UniRac 1 Solarmount Standard Solarmount Light Solarmount HD WEEB DMC UL file no QIMS2 E351343 IronRidge 2 Standard Rail XRS...

Page 12: ...12 Appendix No Rail Washer Clamp Compatibility WEEB KMC Everest 3 CrossRail 48 CrossRail 38 WEEB PMC UL file no QIMS2 E351343 UL file no QIMS2 E351343 ProSolar 4 Rooftrac Groundtrac ...

Page 13: ...ionally Important Notes 1 The NEC section 690 43 states Exposed non current carrying metal parts of module frame equipment and conductor enclosures shall be grounded in accordance with 250 134 or 250 136 A regardless of voltage 2 Use general purpose anti seize compound on fastener threads when installing WEEBs 3 WEEBs are intended for SINGLE USE ONLY Functionality will not be guaranteed if reused ...

Page 14: ...om http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II A3 N UL V5 EN 201308 ...