3-17 CAP DUCT MOTOR REPLACEMENT
1) Separate the Housing of the Cap Duct Motor.
3) When replacing the motor, check the position of the door
duct and the link for proper fit.
Link
Duct Door
Cap Duct Motor
NG Position
2) Unscrew 3 screws to disassemble the motor.
4) Insert 2 screws.
5) Push housing aside.
3-16 SUB PWB FOR WORKING DISPENSER
1) Disconnect the wire harness.
2) Remove 1 screw from PWB and replace with new PWB.
CAUTION:
Make sure that the motor housing is taped to
the mold, if not positioned correctly the cover will not fit
properly.
Figure 36
Figure 37
Figure 38
Figure 43
Figure 42
Figure 41
Figure 40
Figure 39
Summary of Contents for LFXS24623B
Page 1: ...REFRIGERATOR SERVICE MANUAL LFXS24623S LFXS24623W LFXS24623B ...
Page 20: ...5 CIRCUIT DIAGRAM ...
Page 85: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 102: ... EV 145C 145F 136D 132P 136A 131A 136B 136C 133A 133B FREEZER PARTS ...
Page 105: ... EV 625A 623B 623B 616J 616J 627D 627B 627A 619A VALVE WATER TUBE PARTS ...
Page 106: ... EV 630J 630J 600C 606A 600A 600B 630F 630A 630H 630G ICEMAKER BIN PARTS ...
Page 107: ...Aug 2014 P No MFL62526051 ...