4-3
Oven lamp
Components
Test procedures
Results
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
5
Ω
± 10%
If not replace
Broil or bake igniter
Oven (safety) valve
Ignition switch
1. Refer to page 3-11, 3-12, 3-13 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: 45
Ω
~ 400
Ω
(Room Temperature
Resistance)
If not replace
1. Refer to page 3-26 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: Approximately
1 ~ 3
Ω
If not replace
1. Refer to page 3-6, 3-7 for servicing procedure.
2. Measure the resistance by rotating the cam of
each switch slowly.
(Multiple meter scale : R x 1)
approximately
40° ~ 80°
other
Continuity
Upside
Downside
Infinite