9-22
CHECKING FLOW CHART BY FAIRURE
Yes
Oven is hot (F-6, F-16)
Remove the relay PCB harness
Check the all the heater relay welded or not. (AND measure the resistance)
Each relay’s TAB and L1.
DLB Relay is measured L2 and TAB.
Normal?
No
END
Replace the oven sensor
Welded
Normal
Continuity
Infinite
Disconnect the power and oven sensor.
Check the oven sensor value
(measure the resistance after cooling down)
Normal:approximately 1.06 k
Ω
at 65°F ~ 1.12 k
Ω
at 85°F
Oven hot error
→
→
F-6, F-16 error
1
Each heater RY
Common