9-7
CHECKING FLOW CHART BY FAIRURE
Oven does not heat (including F-9, F-19 Error)
Measure the Resistor of each heater Between the DLB
Relay’s L2 and each heater Relay’s Harness point of Figure 1
(
①, ②, ③
and
⑤
)
(measure the resistance after cooling down)
Normal
UPPER
LOWER
Bake
Broil
Broil
Bake
Conv.
1
2
Resistor
Min
Max
upper Bake
22.0
29.0
upper broil
45.0
55.0
lower conv.
25.0
32.0
lower bake
20.0
25.0
lower broil
12.0
17.0
UPPER
LOWER