Product Configuration and Information, Size

Product Size

“B”

“C”

“A”

(Unit: mm)

Category

4 inch

6 inch

8 inch

Ceiling Cut-out Ø 100±5 Ø 155±5 Ø 200±5

“A”

Ø 120

Ø 180

Ø 223

“B”

90

145

187

“C”

88

100

111

Product Configuration

Converter

Diffuser Plate

Main Body

Spring

Front Cover

 Product Configuration may vary depending on the product.

Product Information

 23W and 37W products are not suitable for covering with thermally insulating material.

 Asterisk(*) will vary by model.

Category

4 Inch

6 Inch

8 Inch

8W

15W

23W

37W

Product

Verification

3000K LD08X730M2B.D00***0 LD15X730P2B.D00***0 LD25X730P2B.D00***0 LD40X730R2B.D00***0
4000K LD08X740M2B. D00***0 LD15X740P2B.D00***0 LD25X740P2B.D00***0 LD40X740R2B.D00***0
5000K LD08X750M2B.D00***0 LD15X750P2B.D00***0 LD25X750P2B.D00***0 LD40X750R2B.D00***0
5700K LD08X757M2B.D00***0 LD15X757P2B.D00***0 LD25X757P2B.D00***0 LD40X757R2B.D00***0

 MFL67082801,REV06,��.indd   8

11. 7. 12.   �� 11:16

Summary of Contents for LD15X740P2B

Page 1: ...leasereadthe SafetyPrecautions priortouseforyoursafety Thismanualisintendedtopreventproductdamageandprotecttheuser ssafety Placethemanualataplacewhereitcanbeeasilylocatedbyallpotentialusers MFL67082801 REV06 indd 1 11 7 12 11 16 ...

Page 2: ...tricitycost Unit EUR Annualmaintenancecost Unit EUR Annualcostreduction ReplacementCost AnnualelectricityCost Downlight LGDown15W Downlight LGDown15W Basedon12hrsoperationperday electricitycost 0 2 kwhand0 54timesreplacement Calculationresultmaydifferbythelampunitprice usageconditionsandproductlifetime EnergySavingbyHigh Efficiency Upto76 energysavingyearlycomparedto conventionaldownlightlamp 19 5...

Page 3: ...on Feelingcomfortableandloweringcooling costscomparedwithconventional downlight Existing light LG DOWNLIGHT WideApplicationCoverage Naturallightwithcomfortforwide application Department store Retail Store Studio Theater Stage Park Parking lot etc 3 reduction 0 hours or Safety Precautions 4 7 ProductConfigurationandInformation Size 8 Installation 9 10 ThingstocheckbeforeRequesting RepairService 11 ...

Page 4: ...rcertainconditions Installacircuit breaker Riskoffireandelectricshock Violationofwarningsmayleadtoseriousinjuryordeath Violationofprecautionsmayleadtolightinjuryorproductdamage Productisheavy Useatrolleywhen transportingthe product Droppingtheproductmaycause productdamageandmalfunction Usewithproper ratedvoltage Riskoffireandproduct damage Donotinstallproduct inplacesexposedto dampness Riskoffire ...

Page 5: ... Cto50 Conly Usingthedeviceinhigh temperatures maycausefire orshortentheLED slifespan Donotstoreina humidarea Riskofproductmalfunctioning Becarefulnotto applyexcessiveforce tothepowercable Otherwise itmaycausethe devicetodroporresultin electricshock Donotrandomly connectthepower polarities Riskofproductdamageand accidents sfollows aution tionsin WARNING Donotexposethe producttowater whencleaningit...

Page 6: ...ctmalfunctioning Neverdisassemble theproduct Riskofaccidentssuchaselectric shockandproductdamage Electricworkmustbeperformedbyacertifiedtechnician accordingto electricaldevicetechnologystandardsor extensionregulations or indoorelectricalwirespecifications andtheinstallationmanual Specificcircuitsmustbeused Inadequatepowercapacityandfaultyelectricworkmayleadtofireorelectricshock WARNING Ifthelamptu...

Page 7: ...ationoftheobject or causefire 7 Donotusethedeviceforpurposesotherthanillumination whichincludewarmingfood dryingclothes usingunderwater usingasasearchlight fishingorotherevents Otherwise itmaycausefireorelectricshock WARNING Donotwipethesurfacewithinflammables suchasalcohol benzene andacetone Donotusethedeviceinplaceswithcorrosivegases Thecolorandthebrightnessofthelampmaydifferevenamongthe samemod...

Page 8: ...on 23Wand37Wproductsarenotsuitableforcoveringwiththermallyinsulatingmaterial Asterisk willvarybymodel Category 4Inch 6Inch 8Inch 8W 15W 23W 37W Product Verification 3000K LD08X730M2B D00 0 LD15X730P2B D00 0 LD25X730P2B D00 0 LD40X730R2B D00 0 4000K LD08X740M2B D00 0 LD15X740P2B D00 0 LD25X740P2B D00 0 LD40X740R2B D00 0 5000K LD08X750M2B D00 0 LD15X750P2B D00 0 LD25X750P2B D00 0 LD40X750R2B D00 0 5...

Page 9: ...lestotheinterior wiringofthebuilding Forfinishingcap use standardizedproducts 2 3 Installation Make sure to turn off the main power switch off the installation space before connection Connect so that the colors of the 3 power cables match LIVE BROWN NEUTRAL BLUE P E GREEN YELLOW Product spowercables Interiorwiringofthebuilding NEUTRAL LIVE P E Completed installation WARNING MFL67082801 REV06 indd ...

Page 10: ... Turnthepowerswitchontoverifythatthe productisworkingproperly 7 10 Insertthepowercableinsuchawaythatthe powercabledoesnotgettangledbetweenthe ceilingsurfaceandtheproduct 4 Sufficientlylifttheproductsothatthespring canbeinsertedontheotherside 5 Installation MFL67082801 REV06 indd 10 11 7 12 11 16 ...

Page 11: ...t won t turn on Checktoseeifthepowerisconnectedorifthe switchisoff It flickers Turnthepoweroff Turnitbackonafteramoment Iftheflickeringproblemstillexists makeaservice request A certain area is dark Makeaservicerequest 11 MFL67082801 REV06 indd 11 11 7 12 11 16 ...

Page 12: ... 5000 5700 K ColorAccuracy CRI 80 BeamAngle 100 degrees Size Ø120X88 H Ø180X100 H Ø223X111 H mm ProductWeight 358 680 720 1360 g InputVoltage AC100 240 V InputFrequency 50 60 Hz MethodofPowerInput Single phasethree wiresystem Dimming Dimmablewith0 10VDCcontrol 1 SourceCurrent 1mA Max PowerFactor PF Min 0 90 Performancemayvarydependingonthemodel LightColorof3000Kislimitedto6 products 1 Some Dimmers...

Page 13: ...ing cable in the box The components of a dimming cable Housing Yeonho SMH250 Pin YeonhoYST025 HS Ferrite Core TDK ZCAT1730 0730 The usage of ferrite core is limited to 6 products Dimmingcable FerriteCore Todimthelamps acompatibledimmershouldbeused Theuseofincompatibledimmerswillresultindamagetotheproducts Pleaseverifywithvendors MFL67082801 REV06 indd 13 11 7 12 11 16 ...

Page 14: ...ailure to follow operating maintenance or environmental instructions prescribed by LGE in writing or services performed by someone other than LGE or an authorized service provider To make a warranty claim contact your local LGE sales representative After contacting your local LGE sales representative you will receive instructions regarding if when and where to ship non conforming Product Failed Pr...

Page 15: ...MFL67082801 REV06 indd 15 11 7 12 11 16 ...

Page 16: ...P No MFL67082801 REV06 MFL67082801 REV06 indd 16 11 7 12 11 16 ...