background image

- 5 -

Perform grounding 

work.

• Risk of electric shock.

Do not install on un-

leveled ceilings.

•  Risk of product falling, which 

may lead to product damage 

and injury to the user.

Block power when 

installing lighting 

device.

•  Risk of accidents such as 

electric shock.

Use the device within 

a temperature range 

of 20°C to 50°C only.

• Using the device in high 

  temperatures  may cause fire 

  or shorten the LED's life span. 

Do not store in a 

humid area. 

• Risk of product malfunctioning.

Be careful not to 

apply excessive force 

to the power cable.

• Otherwise, it may cause the 

   device to drop or result in       

   electric shock. 

Do not randomly 

connect the power 

polarities. 

•  Risk of product damage and 

accidents.

Safety Precautions

The meanings of the signs displayed on the product and user manual are as follows 

•  This sign indicates operations that might be dangerous and needs care with caution. 

For parts with this sign, user must read the manual carefully and follow instructions in 
order to avoid risks. 

• This sign displays risks involving electric shock under certain conditions. 

WARNING

Do not expose the 

product to water 

when cleaning it. 

• Risk of fire and electric shock. 

 MFL67082801,REV06,��.indd   5

11. 7. 12.   �� 11:16

Summary of Contents for LD15X740P2B

Page 1: ...leasereadthe SafetyPrecautions priortouseforyoursafety Thismanualisintendedtopreventproductdamageandprotecttheuser ssafety Placethemanualataplacewhereitcanbeeasilylocatedbyallpotentialusers MFL67082801 REV06 indd 1 11 7 12 11 16 ...

Page 2: ...tricitycost Unit EUR Annualmaintenancecost Unit EUR Annualcostreduction ReplacementCost AnnualelectricityCost Downlight LGDown15W Downlight LGDown15W Basedon12hrsoperationperday electricitycost 0 2 kwhand0 54timesreplacement Calculationresultmaydifferbythelampunitprice usageconditionsandproductlifetime EnergySavingbyHigh Efficiency Upto76 energysavingyearlycomparedto conventionaldownlightlamp 19 5...

Page 3: ...on Feelingcomfortableandloweringcooling costscomparedwithconventional downlight Existing light LG DOWNLIGHT WideApplicationCoverage Naturallightwithcomfortforwide application Department store Retail Store Studio Theater Stage Park Parking lot etc 3 reduction 0 hours or Safety Precautions 4 7 ProductConfigurationandInformation Size 8 Installation 9 10 ThingstocheckbeforeRequesting RepairService 11 ...

Page 4: ...rcertainconditions Installacircuit breaker Riskoffireandelectricshock Violationofwarningsmayleadtoseriousinjuryordeath Violationofprecautionsmayleadtolightinjuryorproductdamage Productisheavy Useatrolleywhen transportingthe product Droppingtheproductmaycause productdamageandmalfunction Usewithproper ratedvoltage Riskoffireandproduct damage Donotinstallproduct inplacesexposedto dampness Riskoffire ...

Page 5: ... Cto50 Conly Usingthedeviceinhigh temperatures maycausefire orshortentheLED slifespan Donotstoreina humidarea Riskofproductmalfunctioning Becarefulnotto applyexcessiveforce tothepowercable Otherwise itmaycausethe devicetodroporresultin electricshock Donotrandomly connectthepower polarities Riskofproductdamageand accidents sfollows aution tionsin WARNING Donotexposethe producttowater whencleaningit...

Page 6: ...ctmalfunctioning Neverdisassemble theproduct Riskofaccidentssuchaselectric shockandproductdamage Electricworkmustbeperformedbyacertifiedtechnician accordingto electricaldevicetechnologystandardsor extensionregulations or indoorelectricalwirespecifications andtheinstallationmanual Specificcircuitsmustbeused Inadequatepowercapacityandfaultyelectricworkmayleadtofireorelectricshock WARNING Ifthelamptu...

Page 7: ...ationoftheobject or causefire 7 Donotusethedeviceforpurposesotherthanillumination whichincludewarmingfood dryingclothes usingunderwater usingasasearchlight fishingorotherevents Otherwise itmaycausefireorelectricshock WARNING Donotwipethesurfacewithinflammables suchasalcohol benzene andacetone Donotusethedeviceinplaceswithcorrosivegases Thecolorandthebrightnessofthelampmaydifferevenamongthe samemod...

Page 8: ...on 23Wand37Wproductsarenotsuitableforcoveringwiththermallyinsulatingmaterial Asterisk willvarybymodel Category 4Inch 6Inch 8Inch 8W 15W 23W 37W Product Verification 3000K LD08X730M2B D00 0 LD15X730P2B D00 0 LD25X730P2B D00 0 LD40X730R2B D00 0 4000K LD08X740M2B D00 0 LD15X740P2B D00 0 LD25X740P2B D00 0 LD40X740R2B D00 0 5000K LD08X750M2B D00 0 LD15X750P2B D00 0 LD25X750P2B D00 0 LD40X750R2B D00 0 5...

Page 9: ...lestotheinterior wiringofthebuilding Forfinishingcap use standardizedproducts 2 3 Installation Make sure to turn off the main power switch off the installation space before connection Connect so that the colors of the 3 power cables match LIVE BROWN NEUTRAL BLUE P E GREEN YELLOW Product spowercables Interiorwiringofthebuilding NEUTRAL LIVE P E Completed installation WARNING MFL67082801 REV06 indd ...

Page 10: ... Turnthepowerswitchontoverifythatthe productisworkingproperly 7 10 Insertthepowercableinsuchawaythatthe powercabledoesnotgettangledbetweenthe ceilingsurfaceandtheproduct 4 Sufficientlylifttheproductsothatthespring canbeinsertedontheotherside 5 Installation MFL67082801 REV06 indd 10 11 7 12 11 16 ...

Page 11: ...t won t turn on Checktoseeifthepowerisconnectedorifthe switchisoff It flickers Turnthepoweroff Turnitbackonafteramoment Iftheflickeringproblemstillexists makeaservice request A certain area is dark Makeaservicerequest 11 MFL67082801 REV06 indd 11 11 7 12 11 16 ...

Page 12: ... 5000 5700 K ColorAccuracy CRI 80 BeamAngle 100 degrees Size Ø120X88 H Ø180X100 H Ø223X111 H mm ProductWeight 358 680 720 1360 g InputVoltage AC100 240 V InputFrequency 50 60 Hz MethodofPowerInput Single phasethree wiresystem Dimming Dimmablewith0 10VDCcontrol 1 SourceCurrent 1mA Max PowerFactor PF Min 0 90 Performancemayvarydependingonthemodel LightColorof3000Kislimitedto6 products 1 Some Dimmers...

Page 13: ...ing cable in the box The components of a dimming cable Housing Yeonho SMH250 Pin YeonhoYST025 HS Ferrite Core TDK ZCAT1730 0730 The usage of ferrite core is limited to 6 products Dimmingcable FerriteCore Todimthelamps acompatibledimmershouldbeused Theuseofincompatibledimmerswillresultindamagetotheproducts Pleaseverifywithvendors MFL67082801 REV06 indd 13 11 7 12 11 16 ...

Page 14: ...ailure to follow operating maintenance or environmental instructions prescribed by LGE in writing or services performed by someone other than LGE or an authorized service provider To make a warranty claim contact your local LGE sales representative After contacting your local LGE sales representative you will receive instructions regarding if when and where to ship non conforming Product Failed Pr...

Page 15: ...MFL67082801 REV06 indd 15 11 7 12 11 16 ...

Page 16: ...P No MFL67082801 REV06 MFL67082801 REV06 indd 16 11 7 12 11 16 ...

Reviews: