background image

www.lg.com

P/NO : MFL68026019
Rev00_031617

OWNER’S MANUAL

Please read this manual carefully before operating
your set and retain it for future reference.

Models : LD156QSD0

DEHUMIDIFIER 

中文

ENGLISH

(1)MFL68026019 영영  2017. 3. 17.  영영 1:26  Page 1

Summary of Contents for LD156QSD0

Page 1: ...MFL68026019 Rev00_031617 OWNER S MANUAL Please read this manual carefully before operating your set and retain it for future reference Models LD156QSD0 DEHUMIDIFIER 中文 ENGLISH 1 MFL68026019 영영 2017 3 17 영영 1 26 Page 1 ...

Page 2: ...hock Do not store or use flammable gases or materials near the dehumidifier Doing so could result in fire or product malfunction This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by person responsible for ...

Page 3: ... could deteriorate Ventilate frequently Keep the area well ventilated especially if you are using a combustion appliance as well Inad equate ventilation reduces the oxygen level in the air Always hold the plug head when pulling the power plug Failure to do so could result in electric shock or injury Do not use excessive force when pulling the extension hose Doing so could result in damage to or de...

Page 4: ...product in direct sunlight or rain The product could overheat causing fire or electric shock Do not touch the product with wet hands Doing so could result in electric shock Position the product on a firm stable surface If the product is on an unstable surface it may vibrate and make noise If the product is tilted or laid down the dehumidified water could overflow and the product could malfunction ...

Page 5: ...dification 12 Silent Dehumidification 13 Spot Drying 14 Laundry Drying 15 Ionizer 15 Defrost Operation 16 Bucket full 17 OFF Timer 18 Lock Function 18 Light Function 19 How to empty water tank 20 HOW TO CLEAN 20 How to clean the exterior and inlet of the dehumidifier 20 How to clean water tank 21 How to clean Antibiotic ultra fine filter 22 HOW TO STORE 23 TROUBLESHOOTING TIPS 1 MFL68026019 영영 201...

Page 6: ...r the dehumidifier may stop running automatically to protect itself from over heating The room temperature increases while the dehumidifier is run ning This dehumidifier does not have temperature control functions The dehumidifier generates heat while operating raising the room temperature by about 2 C or 3 C depending on the usage conditions room air pressure and room size The dehumidifier can be...

Page 7: ... the wind Antibiotic ultra fine filter Wheels for moving Power plug hanging part Inlet Hose cover Power plug It absorbs the air and moisture in the room h The components are at the top part of the product packaging box Extension hose Shoes drying hose Laundry drying hose Back side NAME OF EACH PART Front side 1 MFL68026019 영영 2017 3 17 영영 1 26 Page 7 ...

Page 8: ...aundry drying mode Smart dehumidification Jet dehumidification Silent dehumidification Spot drying Laundry drying Smart dehumidification Ionizer button It is used to remove harmful bacteria in the air Humidity control button It controls the desired humidity 30 70 Humidity control can be set in the units of 5 Wind strength control button It controls the wind strength OFF timer button The product wi...

Page 9: ...g heating function Heat is generated during the operation so the temperature may be increased by about 2 C 3 C according to the usage conditions indoor temperature size of the room Operation will restart after 3 minutes If it is restarted right after the stop the compressor will start about 3 minutes after to protect the product It automatically protects the product during the continuous operation...

Page 10: ...dicator lamp is lighted The selected operation mode starts after 3 seconds Press Humidity Control button to change humidity Desired humidity can be set to 30 35 40 45 50 55 60 65 70 Humidity can be set with the units of 5 During the humidity setting desired humidity is displayed on the humidity display part and the current humidity is displayed after about 5 seconds Current humidity is displayed i...

Page 11: ...midification To maintain pleasant indoor condition If you press Operation Mode button to select Smart dehumidification mode and set the desired humidity it maintains the humidity set by the user The compressor starts and dehumidification operates only when the desired humidity is lower than the current humidity If the current humidity rises it starts dehumidification operation again The wind stren...

Page 12: ... if you select humidity or wind amount button it switches to Smart dehumidification When you select Jet dehumidification the desired humidity is set to 50 If it changes from Smart Silent dehumidification to Jet dehumidification the desired humidity selected in another operation mode is set Silent Dehumidification When you want dehumidification in silent mode Press Operation Mode button to select S...

Page 13: ... the extension hose Spot Drying When you need spot drying of shoes closet etc Press Operation Mode button to select Spot drying mode In Spot drying mode the louver is closed Wind amount is set to high wind and humidity control is not operational but only the wind amount setting is possible The current humidity is displayed in the humidity display window Use the product by connecting shoes drying c...

Page 14: ...ndry Drying When you want to dry laundry etc continuously regardless of the ambient humidity Press Operation Mode button to select Laundry drying mode The wind strength is set to high wind you cannot set humidity but you can set only wind strength During the laundry drying louver operates up and down CAUTION When you dry laundry be careful not to have water of the laundry drop onto dehumidifier 1 ...

Page 15: ...ide the product Compressor is stopped during the automatic defrost operation ENGLISH Ionizer When you want to remove harmful bacteria in the air Select it by pressing Ionizer button It removes harmful material in the air such as bacteria virus etc using ionized air You can use Ionizer function and dehumidification function at the same time Ionizer can be used at any time regardless of dehumidifier...

Page 16: ... when you insert water tank again bucket full lamp is turned off and operation starts again automatically CAUTION Cautions when you drain the water Carefully take out the drain water tank If you pull the water tank too hard the water inside may spill over When you take out the water tank make sure to stop the product If you take out the water tank during the operation compressor will stop and fan ...

Page 17: ...me goes When it passes the selected time operation stops To cancel OFF timer If you press OFF timer button until the time display disappears in the OFF timer display part it will be cancelled CAUTION Drain the water inside the water tank and then set the time If water tank becomes full during OFF timer operation bucket full indicator lamp is lighted and the dehumidification stops 1 MFL68026019 영영 ...

Page 18: ... your hand when the buzzer sounds 1 time after 3 seconds it enters Lock func tion CL display in the display panel is maintained for 5 seconds It maintains the operation state at the time of setting the function until the function is turned off and there will be no response even if a button is pressed If you press other buttons in Lock function set state warning sound is generated 3 times and CL di...

Page 19: ... is less moisture in the air so dehu midification amount is also decreased When you take out the water tank make sure to stop the product If you take out during operation the compressor will stop and the fan operates for 3 minutes to vaporize the re maining condensed water inside the heat exchanger before complete stop How to empty water tank Hold the top handle of the water tank and softly take i...

Page 20: ...uum cleaner or soft brush How to clean water tank Press the fixing part on both sides of the water tank to take out the lid Wipe the water inside the water tank Soft cloth Do not open the lid There is a float to detect full water inside HOW TO CLEAN 20 ENGLISH CAUTION Do not use the following material It may damage the exterior thinner ben zene acid sponge etc CAUTION If the float is fallen off or...

Page 21: ...h antibiotic ultra fine filter to the right to take it out Completely dry in shade push to the left until the antibiotic ultra fine filter is not pushed any more Clean the antibiotic ultra fine filter with vac uum cleaner or soft brush If the contamination is severe wash with water using neutral detergent Do not use hot water of 40 C or higher The cleaning period for antibiotic ultra fine fil ter ...

Page 22: ... the filter If it is dried under sunlight it may be deformed During the drying avoid fire or direct sunlight but dry in shadow After drying at a place without direct sunlight and with good ventilation for about half a day make sure to store with covering it up and have it stand straight up to prevent dust entering A separate cover for product storage is not provided 1 MFL68026019 영영 2017 3 17 영영 1...

Page 23: ... place in the winter and in dry areas Remove the obstruction Clean the filter Humidity does not seem to decrease much even though the product is run ning in dehumidifi cation mode Is the door window open Is the room too big Is there an object generating steam nearby Close the door window Use the dehumidifier in an adequately sized room Do not use the dehumidifier together with other appliances The...

Page 24: ...24 ENGLISH 1 MFL68026019 영영 2017 3 17 영영 1 26 Page 24 ...

Page 25: ... 1 MFL68026019 영영 2017 3 17 영영 10 55 Page 100 ...

Reviews: