- 16 -
4) Tub
Turn the air guide nut counter-clockwise.
(Special tool might be needed.)
Be careful the rubber packing of air
guide assembly should not be lost.
Turn the softner cap and nut counter-
clockwise.
Remove 4 screws for sump holder .
Remove side 8 screws.
Remove 2 Earth screw of right side.
Lift tub assembly upward.
(Be sure water softner is not blocked.)
Be careful not to be injured or scratch
floor by the sharp edge of tub.
8. Air Guide Assembly
Disconnect the wiring connection.
Remove 3 hoses assembly.
Be careful the o-ring should not be lost.
9.Water softner
1) Remove the hose assembly.
2) Lift it upward.
Be careful not to wet the floor by the
water left in the water softner.
3) You can disassemble the regeneration.
valve by unscrew the 2 screw.
Be sure not to lost the spring and bobbin.