No Power on when the power button pressed.
The plug is correctly
NO
inserted in the
Socket-Outlet?
YES
The Fuse or NO
Circuit Breaker
of house is O.K?
YES
The Thermal Fuse NO
is O.K?
YES
The Power Switch or NO
the Circuit is O.K?
YES
The C-Trans Circuit NO
is O.K?
YES
• Insert the Plug Correctly.
• Check the electricity is failed or not.
• Replace the Fuse or Circuit Breaker of house.
• Check the Thermal Fuse and replace it.
• Check the Power Switch or the circuit and repair it.
• Check the C-Trans Circuit. and repair it.
C h e c k t h e C o n t r o l l e r. ( P o w e r C i r c u i t )