Step3: Generate 802.11b/g/n continuous symbol
(1)Please re-type the Step5 (1)~(4) commands.
(2)Command 17 1 13
17: Set continuous mode.
1: Enable data rate
13: 54 Mbps, other data rate, please refer the above table.
After you type above command, you can measure the 802.11b/g continuous symbol in
your RF test instrument.
(3)Command 17 0
Stop transmitting continuous signal
Step4: Test RX sensitivity
Before test RX, the Marvell standard waveform is needed.
(
1) Command 12 1
12
: Choose RX text channel
1
: Channel number,
(1~11 for B/G/N mode)
(2) Command: 112 0 (only for N mode)
112
: N mode HT20/40.
0
: for HT20/40. 0
_
HT20, 1
_
HT40
(3) 32:
Check the received packets.
(4) 31:
Clear all the received packets.
Step5: Others Commands
(1) Command 45
_
Check the MAC
(2) Command 99
_
Quit the test mode/ Quit the MFG tool