26
eLectricaL connectionS
(cont.)
I N S TA L L AT I O N I N S T RU C T I O N S
4-WIRE GROUNDED JUNCTION BOX
Cable from power supply
Ground
Wire
Red
wires
Black
wires
White wire
(no connection)
Junction box
Green wire (ground)
Cable from cooktop
UL-listed conduit
connector
Observe all governing codes and local
ordinances.
1
Disconnect the power supply.
2
At the circuit breaker box, fuse box or
junction box, connect appliance and power
supply cable wires as shown.
WARNING
If connecting to a 4-wire power supply
cable electrical system, the appliance
frame connected ground wire MUST NOT
be connected to the neutral wire of the
4-wire electrical system.
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996
NEC), MOBILE HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES
DO NOT PERMIT GROUNDING TO THE NEUTRAL (WHITE) WIRE
2
Carefully lower the cooktop into the counter-
top cutout, making sure not to trap any wires.
NOTE: Do not use caulking compound. The
cooktop must be removable, should service
be required.
1
Visually inspect the cooktop for damage.
Make sure all cooktop screws arve tight
(see below for locations).
Screws
cooKtoP inStaLLation