IMPORTANT INSTALLATION
INFORMATION
•
All electric cooktops run off a single phase,
three-wire or four-wire cable, 240/208 volt, 60
hertz, AC-only electrical supply with ground.
•
Minimum distance between cooktop and
overhead cabinetry is 30″ (762 mm).
•
Make sure the cabinets and wall coverings
around the cooktop can withstand the
temperatures (up to 93°C [200°F]) generated
by the cooktop.
** Do not obstruct these areas!
36 inch Radiant Cooktop
4" X 8" (102 mm x 203
mm) opening to route
armored cable if panel is
present.
30″ Min.
(762 mm)
LCE3610SB Radiant Cooktop
Unit
A
B
C
D
E
F
G
H
I
J
K
L
Min
Min
Max
Min
Inch 36-11/16 21-15/16 3-3/4 33-27/32 19-25/32 34-9/16 20-3/8 13/16
13
5-23/32 2-1/2
24
mm
932
557
95
860
502
878
517
20
330
145
64
610
All dimensions are stated in inches and millimeters (mm).
Allow 2″ (50 mm) space below the armored cable opening to clear the electric cable and allow
space for installation of the junction box on the wall at the back of the cooktop.