22 Cassette type Air Conditioner
2. Adjusting air volume to the height of ceiling
You can choose the RPM(or air volume) of indoor motor according to the height of ceiling to
supply the comfortable atmosphere to consumers.
Procedure
1. Choose the selectable position in the table after measuring the height of ceiling.
2. In the case of changing the height as "high" or "low", open the rear cover of the wired remote-
controller.
3. Move the slide switch to the set position.
4. Close the rear cover and check if it works normally.
Optional Operation
Ceiling height
Mode of slide switch
Change of air volume
Remark
more than 3.3m
High Ceiling
Increasing
2.7~3.3m
Standard
-
Manufactured in
less than 2.7m
Low Ceiling
Decreasing
standard mode
Slide switch for ceiling height
1
2
3
1
2
3
1
2
3