8-3 Poor cooling in Fresh food section
No
1
Checking flow
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the fresh food door and Check the
air flow.
The sensor is determined by
the temperature.
For example, 30kΩ indicates 32°F.
Result & SVC Action
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Action
Go to the 4
Check the F Fan motor
Check the damper
(Go to the 5)
4
Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
<Swing Model>
<Drawer Model>
1-. Unplug connector from
.
2-. Check resistance between wires
.
CON7
White
to White
32