- 22 -
2) Indoor Unit Installation (Standard type)
The mounting wall should be strong and solid
enough to protect it from the vibration.
1. Mount the installation plate on the wall with
four Type "A" screws.
(If mounting the unit on the concrete wall, consid-
er using anchor bolts.)
• Always mount the Installation plate horizontally
by aligning the marking-off line by means of the
thread and a level.
2. Drill the piping hole with 70mm dia. holecore
drill.
• Line according to the arrows marked on lower
the left and the rght side of the Installation Plate.
The meeting point of the extended line is the
center of the hole.
• Drill the piping hole at either the right or the left
and the hole should be slightly slant to the out-
door side.
Installation Plate
marking-off line
Thread
Weight
Type "A" screw
ø70mm
ø70mm
5~7mm
A
A
A
A
ø70mm
ø70mm
50mm
20mm
20mm
80mm
Indoor
Outdoor
Wall
Left rear piping
Right rear piping
Left rear piping
Right rear piping
The lower left and the right side of
Installation Plate
LM-1830C2L/M, LM-1830H2L/M
LM-2430C2L/M, LM-2430H2L/M
Summary of Contents for L2-C243AL1
Page 52: ... 52 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Page 53: ... 53 2 Outdoor MAIN P C B ASM ...
Page 54: ... 54 3 Display Ass y ...
Page 55: ... 55 Schematic Diagram 1 Indoor ...
Page 56: ... 56 2 Outdoor ...