4.5.4 Checking PAM Block
PAM control signal
PA_ON : PAM Enable
PA_RO: PAM Gain Control
PAM IN/OUT Signal :
When PAM is under the operation of high power mode (PA_R0:Low),
PAM OUT power must be over 21 dBm
PAM IN power must be under 10 dBm
PA_ON must be HIGH (over 2.6V)
PAM_IN
PAM_OUT