4. TROUBLE SHOOTING
- 96 -
For testing, Max power output is needed.
Set the Phone Tx is ON
and PDM is 450
Check TP1
Over 21dBm ?
Change the board
RF Tx Level is OK
Check FEM
Check PAM Block
Refer to 3.5.4
NO
YES
Check TP2
Over 19dBm ?
NO
YES
Check TP3
Over 15dBm ?
NO
YES
Check TP4
Over -5dBm ?
NO
YES
Check Duplexer