Note1) The abnormality of RT-Sensor, R2-Sensor Icemaker Unit, and Icemaker-Sensor is not indicated in trouble code but it
is indicated when checking LED (when pressing both freezer temperature control button and refrigerator temperature
control button for more than 1 second at the same time).
RT-Sensor
Normal : A LED on,
Abnormal : A LED Off.
R2-Sensor
Normal : B LED on,
Abnormal : B LED Off.
Icemaker Unit
Normal : C LED on,
Abnormal : C LED Off.
Icemaker Sensor
Normal : D LED on,
Abnormal : D LED Off.
2-16. Test Function
1. The purpose of test function is to check function of the PCB and product and to search for the failure part at the failure
status.
2. Test button is placed on the main PCB of refrigerator (test switch), and the test mode will be finished after maximum 2
hours irrespective of test mode and then is reset to the normal status.
3. Function adjustment button is not perceived during performance of test mode but only warning sounds ring.
4. In finishing test mode, always pull the power cord out and then plug-in it again for the normal state.
5. If nonconforming contents such as sensor failure are found during performance of test mode, release the test mode and
display the failure code.
6. Even if pressing the test button during failure code display, test mode will not be performed.
MICOM FUNCTION
- 30 -
The rest of LEDs
are all on.
Test 1
Test 2
Normal
Conditions
MODE
HANDLING
CONTENTS
REMARKS
Press TEST s/w once.
Press TEST s/w once at
TEST1 conditions.
Press TEST s/w once at
TEST2 conditions.
1. Compressor continuously operates.
2. Freezer fan (high speed RPM), Cooling fan
continuously operates.
3. Defrost heater is off.
4. All display LEDs are on.
5. Stepping motor damper is in open
conditions. (baffle is open)
1. Compressor is off
2. Freezer fan, Cooling fan are off.
3. Defrost heater is on.
4. All display LEDs are off. (Freezer room “2”
LED and Refrigerator room “2” LED are
only ON.)
5. Stepping motor damper is in closed. (baffle
is closed).
Returns to the initial conditions.
- Forced operate.
- Freezer fan is off when
door is opened.
- It returns to normal
conditions when the
temperature of defrost
sensor is above 5°C.
- Forced defrost.
Compressor starts after
seven minutes delay.
Summary of Contents for GR-L208NN
Page 42: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 42 ...
Page 48: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 48 ...
Page 49: ...3 2 Parts list 1 GR L207ERA GR L247ERA EXPLATION FOR MICOM CIRCUIT 49 ...
Page 50: ...EXPLATION FOR MICOM CIRCUIT 50 ...
Page 51: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 51 ...
Page 52: ...EXPLATION FOR MICOM CIRCUIT 52 ...
Page 54: ...EXPLATION FOR MICOM CIRCUIT 54 ...
Page 55: ...2 GR B207ERA GR B247ERA EXPLATION FOR MICOM CIRCUIT 55 ...
Page 56: ...EXPLATION FOR MICOM CIRCUIT 56 ...
Page 63: ...CIRCUIT 63 ...
Page 64: ...CIRCUIT 64 ...